2 Ciena’s intelligent control plane allows the network to automate and distribute many functions formerly performed through a combination of centralized management systems and manual processes. 22K how do I obtain proper console cable db-9 to rj-45 cable for the console. 6500-T12/T24. From MCP 5. You must configure the Route Recorder before configuring any other appliances in your deployment. raciena6500. Step 6: Repeat steps "3" & "4". Select displayTimezone. 03 User Guide-Part B (Designing a Photonic Network), 450-3550-004. I also found a doc but for CPL and not 6500 : TID Consolidation Reconfiguration Procedure (Issue 1. Supports 4 GbE NNI/UNI ports including 2 100/1000 Base-X SFP ports and 2 dual-mode ports: RJ-45 10/100/1000 Base-T and 100/1000 Base-X SFPs. MCP presence of pre-5. If the active flag is "unknown" then that is the root of the issue. SP w/access panel (SPAP) SP w/access panel (SPAP-2) w/2xOSC 2xSFP. 10) from Ciena Corporation. a. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots enabling customized configurations for the strictest connectivity requirements at the access Repacking the Switch. click on the PDF icon to download the Web Site Manager for 6500 Windows. Step 7: Compare the "Laser Centering" configured on both ends, they need to MATCH. The following commands are used for the Cisco router configuration for the Collector. The Ciena 6500 Packet-Optical Platform is a multi-port multi-protocol system that supports TDM/WDM/GigE/10G/40G and 100G ports. 6500-D14/S14 6500 Packet-Optical Platform. pdf". blueplanet. Select the application “raciena6500” with the name "Auto accept new SSH Key". Using the MCP UI, select Network > Network elements operations. 0_Planning)_Issue1) Expand Post. resourceTypes. In 6500 14-slot shelf, you cannot check complete configuration via single command. OME6500 (All Platforms) : Alarm Clearing Guide. Step 2: At SNC originating node Edit the SNCG and change its Primary State from IS to OOS. No service management (no DVT or Prov’g for SONET/SDH switching) 6500. 43 and Transport Interface 4X10G OTR 4X XFP/4X SFP+ with Encryption, we need to know if these Ciena DWDM have compatibility to connect to SAN Cisco MDS 9706 Multilayer Director with. By configuring VLAN interfaces on the Network and Interface Configuration page, you can ensure compatibility with network installations in which the switches present multiple VLANs on a port. Then locate the product and SAOS version. WaveLogic Ai, the industry’s first programmable 400G, paves the way. The Brocade was providing R_Rdy, Ciena was simply doing pass-through. With dense 100GbE to 400GbE aggregation, support for 1/10/25GbE, and WaveLogic™ 5 Nano (WL5n), the 8110 addresses the increasing need for high-capacity routing and switching applications. 3_Admin_Security)_Issue1. (There are guides for the 4200. Choosing a Ciena OME 6500-D2 will increase your network support on the Ciena OME 6500-D7/S8 configuration allowing you to bridge the ethernet, WDM and TDM rack configurations providing the capacity to meet web-scale demand, as well as Ciena's 6500 Optical Platform Converges package, optical transport For 6500 Photonics OTS link (Fibre) and OMS link (ROADMLine), there are a few rules governing the total capacity: A maximum C-band allocation is 191. Click Add, specify the values in the following figure and table, and click Save. this should bring up all of the cards that are provisioned on the node. 2) (ciena. This is from the Installation/Ordering documentation for the 6500 32-slot shelf (if you ordered from Ciena): Included lugs are Hubbell/Burndy p/n YAV2CL2NT10FX90 (Copper Compression Lug, Narrow. MEF CE 2. Failure Analysis Configuration. License Server: License check request timed out. AIPA Install Procedures; Creating the bpadmin user;. Ciena Operational Commands. License check request timed out; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our. Photonic Layer Guide, Part 2 of 3 Release 12. 93 nm to 196. The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to full rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per. The Routing/Label distribution protocol setup (ISIS/ISIS-SR/LDP/OSPF) must be available. MCP supports the following TAPI object types. We are covering Ciena 3900 series (3902, 3916, 3920, 3930, 3940, 3960, etc. September 28, 2020 at 3:44 PM. using Ciena’s 6500 optical coherent technology, the 400G Waveserver provides a low -cost. Resolution/Answer. Performing a facility or terminal. x. Via the Live Support Chat button on Support page. 2 December 2021, Version 1 Issue/Question What prechecks should be completed prior to a 6500 installation Environment 6500 Installation pre-checks Resolution/Answer The. 6500 family Power Options Redundant breakered/fused 3x60A power cards Redundant breakered/fused 4x60A power cards (NTK603AB only)Verification Logs - Free download as Text File (. Download Data sheet 6500-D4 Packet-Optical Platform The 6500-D4 is a compact chassis that is designed to. It shows the mac table in your PC. Step 7. Built-In Test. 38 nm for a total of 4825 GHz of spectrum. pdf) or read online for free. 5” or 10 x 2. ajay m (Customer) asked a question. View and Download Ciena 3930 Series hardware installation and start-up manual online. I have searched the "maze" of technical documents on Ciena library but can't find. For detailed instructions regarding Site Manager Security and Administration, including a more detailed login procedure, see 6500 Packet-Optical Platform Administration. For more details on the command line, please refer to "323-1851-193_(6500_R12. CLI configuration to enable challenge-response. In today’s on-demand world, your network needs to adapt to thrive. Hi, We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Instructions on how to connect to the console port are in the Module Installation Guide. ) The Ciena 6500 Packet optical platform 2-Slot , 7-Slot ,14 Slot and 32 Slot Box is widely used . conf file, as required. 3802 XGS-PON Optical Network Unit. With the ability to scale to Terabit/s switching per slot, Ciena's 6500 T-Series Packet-Optical Platform addresses the growing need to maintain profitable delivery of converged packet and OTN services on demand, for a superior customer experience. 6_CLI)_Issue1. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. ONID. In multi-unit deployments, you have the option of using the master unit as the authentication server for the client units (using TACACS+). Enter to Configuration mode of the device (config terminal, for example). Pre-upgrade 6500 NE either Now or Schedule to be executed at a later time. Ciena’s Coherent ELS is a coherent-optimized Open Line System (OLS) designed to meet next-generation photonic requirements at the network edge. Ciena’s 6500 supports both muxponder and central fabric-based packet and OTN switching solutions; operators can cost optimize the configuration based on traffic requirements, selecting to express wavelengths or aggregate and switch sub-rated ports where needed, without compromise. Log in to Host 0 as bpadmin user and navigate to /opt/ciena/loads/7. It shows the mac. The FR configuration section appears. rais12000. Remove the switch from the packaging materials. Select BGP in the configuration hierarchy. Architected for high-capacity applications, Ciena’s 6500-D14/S14 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with unconstrained hybrid. What’s inside. x (Catalyst 9300 Switches) Chapter Title. It provides highly dense ROADM and amplifier configurations. Click Save. (!!!) Card physically Jack out & Properly Jack in. com) I guess it is not the same procedure and there are differences between CPL and 6500 procedure. Steps. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. x. Not sure if i can share the document here but it contains the following topics related to TACACS Filename: 323-1851-301_(6500_R12. 6500 Network Element fails to get license from License Server. The 6500-D2 is part of the 6500 Family of Packet-Optical Platforms, which offers multiple chassis form factors to provide flexible, cost-optimized configurations to best match site-specific requirements. Set the Router ID. Document Date Engineer Writer Reason for Change. OneControl : 8700 and 5170 nodes are constantly resyncing; Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance. Checking the system state of Site A and Site B. 2) (ciena. Multiple configuration options with fully modular 4-slot or 10-slot chassis variants. Overview; Required files; Required users; Prerequisites. Hello Huy, you can check the software status on this node in Release Management under configuration. pdf. To offer flexible, cost-efficient deployment options, the 6500-D14 is tailored for photonic/transponder applications combined with muxponder card-based packet/OTN switching, while the 6500-S14 can also be optimized for packet/OTN centralized switching deployments, with the ability to tune for packet and/or OTN in any ratio. 50DWDM stands for dense wavelength division multiplexing and is a point-to-point system where you can send multiple wavelength on a single fiber. Anyone know why we do not see this option? Other nodes have it. Stay Connected. Hello community. Step 1: Click on the Configuration tab in Site Manager. Procedure to replace a power card in a 7 slot 6500 chassis. *. Click Edit. I have observed 6500 raising High Temp alarm whenever SP card reports temperature beyond 40degrees C irrespective of Site Temperature. XDMCP (X Display Manager Control Protocol) opens a single port in this range. Network Element should have ISIS (or any other IGP protocol) commissioned and SR Enabled. 6500. Catalyst 6500 Series Switches Installation Guide. This architecture capacity. 2 card-based packet/OTN switching hardware is available for. show slots 5 config pwr-profile set ciena-6500r-slots:slots "5" config pwr-profile "1,BAND-C" target power "1" p -14. Step 5:. Links and/or nodes are systematically failed along paths in the topology based on configured settings. Funcionality. mcpc file to the required folder on your computer. Zones are configured underneath the top-level domain. The 6500 T-Series leverages the programmability of Ciena’s industry-leading WaveLogic™ Ai coherent technology, enabling operators to maximize fiber capacity and lower the cost of When the expected far-end address (FEA) is set on a 6500 CMD Tx adjacency facility, the Wave-Line Synchronizer application discovers the proper type of transmitter and autoprovisions basic configuration information, such as the transmitter type (for 6500), wavelength, nominal power, transmission mode (for WaveLogic Ai/WaveLogic 5e interfaces on. single command to install; auto configuration • Line interface – 2 x Wavelogic3 Modems with a 200Gbs port , 16QAM DWDM channels, C -Features and benefits. The following topics for non-DOC-controlled systems: Topology Fundamentals Photonic Optical Control Photonic Applications Photonic Engineering Rules Photonic Set-Up Guidelines Provisioning Examples See Part 1 for the following. To reset the switch to factory default, issue the e rase startup-config or write erase command. the 6500-D7/S8 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with packet/OTN switching and an intelligent control plane for cost-effective. Clear Procedure: Restore the connectivity between sites; specific corrective action will depend on the cause of the outage (e. A backup profile contains details of the backup process, backup transfer locations and number of backup files to be maintained for the NE. conf file by entering: cp -p logrotate. Edit the information in the fields shown in the table below, as required. Click Save. Term Definition TL1. Make sure the FTP port on the computer is unblocked. 2Tb/s of switching capacity. @Note: Please make sure that third party network are transparent for GCC1 and GCC2. Advantages of Ciena’s packet/OTN switched solutions include:The Flow Recorder supports both Netflow and sFlow (including sFlow v5) protocols. • Viewing the Configuration Hierarchy. See “Configuring SNMP v3 Profiles” on page 3-48 for instructions on creating SNMP v3 profiles. The following is the sequence of steps performed for 6500 upgrade in MCP: Download 6500 software from to a file server. OneControl : 8700 and 5170 nodes are constantly resyncing. Data sheet Watch video. 03 User Guide - Part A (Common), 450-3550-004. When an E-Line’s MPLS mode is set to VPWS, the service can avoid MAC learning and can support internal loopbacks. Ensure that the “version” for each of the “additional_solutions” matches that displayed in step 10. yml file and exit the text editor. MCP: Policy management for updating license server on network elements. these benefits across 6500 hardware that supports compact WaveLogic 5 Nano 100G/200G CFP2-DCO pluggables. Perform the following steps to create a backup maintenance profile using the MCP UI. 6500 : Packet Configuration Integrity Fail. Scroll down to your CMD44, it should be located in slot CMD44-1-83 or something similar. Installing the Ciena Linux system bundle for Site B; Importing license server certificates; Static IP. Figure 3. com) I guess it is not the same procedure and there are differences between CPL and 6500 procedure. To turn off paging =. Network Element should not be allocated with any SID value. Navigate to System > Technical documentation > APIs > UAC. The SONET/SDH services must be tolerated by MCP. • NTK703PA-F01: 6500-T24 Shelf mounted at 3-38U in a 23-in 44U EIA Rack (26x18x84in, Blue) on a cushioned pallet packaged for vertical shipping. From there, you'll find 6500 related folders and can drill down based on release and more. Ciena 6500 | OTN Standalone License Server: 6500 Network Element fails to get license from License Server License Server: not able to add "Floating IP" onto a pair of LS in HA. Ciena’s 8700 Packetwave® Platform—a multi-terabit programmable coherent DWDM packet switch—addresses the growing need to efficiently aggregate and switch large quantities of packet traffic while guaranteeing stringent Service Level Agreements (SLAs), revolutionizing the capital and operational. x. Number of Views 6. required port configuration setting for the Brocade to properly interact with the 6500. Sole title to the Software and documentation, to any derivative works, and to any associated patents and copyrights, remains with Ciena or its licensors. In MCP a Node maps to a single physical device. 6500 only supports GMT. All while taking up less space. It provides highly dense ROADM and amplifier configurations so you can quickly react to unpredictable traffic requirements by scaling nodal connectivity. For detailed instructions regarding the installation of Site Manager, see Site Manager for 6500 Packet-Optical Platform and Common Photonic Layer Fundamentals (323-1851-195). Local authentication is always used as a fallback in the event that authentication through a remote. mac show. Ciena 3916 Configuration. The Catalyst 6000 series switches (Catalyst 6006 and Catalyst 6009 switches) are described in a separate publication, the Catalyst 6000 Series Switch Installation Guide. MCP does not use this value. Configure the following settings. By continuing, we assume that you consent to receive all cookies on all Ciena websites. Ciena’s Blue Planet Manage, Control and Plan (MCP) provides end-to-end network and service lifecycle management acrossStep 5: Login to the far end OME 6500. 6500-2 6500-D7 6500-S8 6500-D14 6500-S14 6500-S32 6500-T12 6500-T24 Figure 2. Configuration settings for the time zone. Advantages of Ciena’s packet/OTN switched solutions include:Steps. 0SY 38 Virtual Private LAN Services (VPLS) • Prerequisites for VPLS, page 38-1 † Restrictions for VPLS, page 38-2 † Information About VPLS, page 38-2 † Default Settings for VPLS, page 38-6 † How to Configure VPLS, page 38-6 † Configuration Examples for VPLS, page 38-18. Here we have configured a Aggregate and this is also in LACP configuration. Note: The procedure number may change depending upon the Release, but the document 323-1851-320 will be the. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. This chapter provides a brief overview of the 6500 Packet-Optical Platform. Issue 1 10/17/2019 JPL JPL First official document release. # it will start re. Note: To manage large network element profiles, Ciena recommends using a 64-bit system for better performance and a better user experience. The layer mapping model can be controlled with the following configuration option. Resolution/Answer. In a multi-unit configuration, the available profiles are those that have been configured on the master unit. CCM status of the service. Ciena’s Mayank Chauhan gives an overview of the latest hardware and software advancements on Ciena’s 6500 D/S-Series platforms, that offer on-going efficienc. Nodal FCAPS) for 5400 NEs that have SONET/SDH cards and services configured on them. Driver Support Document. The 6500-T12/T24 shelves, operate with the robust and feature-rich 6500 software, and support high-density, high-capacity hardware modules. During case creation if the case being created is determined to be a minor case. Support for RLS L-Band C-Band was added to MCP 5. 1. To update on demand, click Refresh . Network admin: full control of network elements and services. . software upgrade is done. 6500. I am currently using 100G QPSK. Download >> Download Ciena 6500 installation guide Read Online >> Read Online Ciena 6500 installation guide 24 May 2013 Our customers recognise and value the benefit of consistent installation quality across all their sites. Select the lineup file to be used for the remainder of this procedure:configuration with ROADM 6500-S8 Packet-Optical with DC power Compact 600G Packet/OTN Switch . Converged Packet Optical 6500 Family OME 6500 : SFP specification sheet 6 July 2021, Version 2 Issue/Question OME 6500 : SFP specification sheet Environment. show slots 5 config pwr-profile set ciena-6500r-slots:slots "5" config pwr-profile "1,BAND-C" target power "1" p -14. Hi Vikash, the command I mentioned above is only related to 6500-PTS. 9 or 10. yml file. Allows a field replaceable module for distributed VNF hosting on an. Log into the MCP UI and select System > Configuration. IS12000. Ciena Commands. The branches in the tree are grouped under a top-level administrative domain, represented by a top-level folder icon on the web interface (shown as “Network” in the following figure). Ciena Operational Commands. Click the Path tab. . most efficient utilization of network resources with the ability can be cost-optimized for specific service connectivity. In 6500 14-slot shelf, you cannot check complete configuration via single command. Use the values in MCP-generated alarms to set or change the alarm severity. 1b. x two-point E-Line services. 2) (ciena. racienaonid. The VNC viewer will display a login window where you should log in using a user name and. 0 and there you find 430 pages of planning guide in PDF format (NTRN10EG. 0 and there you find 430 pages of planning guide in PDF format (NTRN10EG. Incorporates on-board RFC 2544 Performance Benchmark. For the LSP name and the Packet service name, certain devices support different alphanumeric characters than the MCP defaults. From 800G performance optics and 400G coherent pluggables to compact ROADMs and control plane automation, you can seamlessly maximize your investment from edge to core. Using the MCP UI, select Network > IP transport. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall. This will add clock types and clock endpoints to the network map. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. Table 2. conf file by entering: cp -p logrotate. Click the Export logs button. The 6500 S-Series shelf configurations are equipped with an agnostic, centralized packet/OTN switched fabric, scaling from 600Gb/s to 3. VPLS is the default value assigned to E-Line services if the BPO-IFD file is not altered. Port 9 is cabled over to the 6500 via optical fiber. The Brocade was providing R_Rdy, Ciena was simply doing pass-through. 1AE-2018 payload encryption for hop-by-hop or end-to-end regardless of the number of intervening devices. 0) Public_IPV6_v1 (6500 specific policy)Ciena 6500 with module Card 4X10G OTR 4xXFP/4xSFP+ Brocade switch is 16Gb DCX 8510-8 at FOS v7. - documentation identifier (0000). 6500 T-Series. 6500 Family; Ciena; Upvote; Answer; Share; 4 answers; 41 views; Top Rated Answers. In order to reach the eMOTR and PKT fabric devices, you need to retrieve the SNMP engine ID either via SNMP (OID 1. pdf Page 121 - Centralized user administration and authentication through TACACS+Service Manual Ciena 6500 - This Service Manual or Workshop Manual or Repair Manual is the technical document containing instructions on how to keep the product working properly. x or x. Select the shelf; Edit the. For the purposes of this. show software. Steps. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots enabling customized. Environment. Number of Views 590. rdp; Driver Tier: 1; Vendor: Ciena. Perform the following steps to create a backup maintenance profile using the MCP UI. The status shows the worst. The following is the sequence of steps performed for 6500 upgrade in MCP: Download 6500 software from to a file server. Resolution/Answer. Step 2: There should be any alarm on these ports. Click Edit. Optionally Disable Soft Recovery Storage of Rolling Alarm Mutations. 2 009-3218-022-Standard Revision A. Standalone License Server: 6500 Network Element fails to get license from License Server; SAOS 8. This Security Policy describes how the Ciena 6500 Packet-Optical Platform 4x10G meets the security requirements of Federal Information Processing Standards (FIPS). Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. I think there is a problem with the default route redistribution between the primary and backup GNE. 7) The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. Tech Touch Video: Live Chat Demo. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. • Ciena’s vSwitch is a Data Plane Development Kit (DPDK)-based switch that provides service function chaining as wellFigure 1. 3. I was curious if others have seen this. Under Security, select Configuration. VPLS is the default value assigned to E-Line services if the BPO-IFD file is not altered. This shows the lines of configuration for the given object. Ciena 6500-D7/S8 Data Sheet Created Date: 2/14/2018 5:43:24 AM. Step 1: Remove the fuse for the power card. Global parameter list. this might help. 0 Product 6110 6130 6150 6500 Optical Metro 3100 Optical Metro 3400. MCP DocumentationFor the first command: Step 1: Login to RLS CLI with an account with proper privilege. We would like to show you a description here but the site won’t allow us. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. Port 4 and Port 9 are on the same virtual-switch and have the same VLAN. Integrates line-rate Service Activation Testing capabilities. MCP: Policy management for updating license server on network elements. Hope this helps. Provides advanced Carrier Ethernet services powered by Ciena’s Service-Aware Operating System (SAOS) Supports two 100/1000Base-X SFP ports and a combo port supporting 100/1000 Base-X SFP and RJ-45 10/100/1000Base-T. About MCP Docs. Low footprint 1RU in a nonblocking architecture with: - 6 x 1GbE/10GbE SFP+ ports - 2 x 100M/1GbE ports. Ethernet Segments details. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. The "Packet infrastructure" window displays, reporting the total number of services. Step 7. Preview. This Ciena 6500 Maintenance and Maintenance Course is designed to provide any student with a solid understanding of the 6500-series platform and its many features and options. I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. icv NO NO 2 aabb. Command strings; Prompts and responses from the systemHi Diego, 6500 needs to be operated within the mentioned Environment guidelines in the planning guide . 2 6500 RA logs can result in 6500 management issues;. In this video Chris Brown will show you how the 6500 PTS simplifies customer TDM-to-Ethernet service migration as needed, without having to replace the. Use the VLANs tab on the Admin > Units page to configure VLAN interfaces. In the BGP Peers section, click Configure Peers. Ciena’s intelligent control plane is deployed in large (1,000+ node) networks with field-measured six-9s (99. Tailored to address enterprise business requirements at the edge, the 6500-D2 Packet-Optical Platform is a compact 2RU chassis that cost-effectively extends the flexibility and resiliency of the 6500 platform from the core to the access. Collector CLI command. Go to Configuration, Backup and Restore. IP Address—Enter an IP address with or without a netmask (x. Need some guidance trying to setup / configure in-band MGMT between two Ciena 6500 nodes. One can use MCP to discover & visualize: EVPN service attributes. Bit Interleaved Parity. ) In this animation shelf vies and Specific fix Slot f. 3. 3_Admin_Security)_Issue1. IfdConfig". It shows the mac. declarative configuration, and platform programmability. by Jojo Ferrer (Employee) 6500 Family. If you provision the 6500 GCC0 against the OTMx port facing other vendor and if not receiving GCC0 byte, the 6500 will raise GCC0 link failure alarm. Ciena’s 5171 Platform empowers advanced access networks with 100GbE packet services beyond the Central Offices and POP sites, enabling deployment into street cabinets and other uncontrolled locations. BIP. x. 1b. Overview; Required files; Required users; Prerequisites. Waveserver Ai Commissioning using the CLI, Quick start for commissioning Waveserver Ai with 323-4002-221 the CLI This quick turn-up sheet can be downloaded via the Waveserver Ai homepage by. 6500 Family;. RLS: How to clear OSRP Link down alarm due to fiber break. # run setpriv # then select on # run omeslat # password will be nortel # Select 1 if you want to preserve the comms settings or 0 if not. ISL port set to 8Gb to Ciena 6500 using standard Brocade shortwave SFP. The 8700 is specifically optimized for 10GbE to 100GbE switching and aggregation, allowing you to deliver higher rate ports, services, and connections to meet market demands. Offers. 6500-7 E-Suite ROADM configuration spectral efficiency and delaying new build-outs, Cienas coherent 40G and 100G solutions operate seamlessly For smaller, simpler network configurations, passive photonics alongside 10G wavelengths, maximizing the traffic-carrying can be used for lowest capital expenditures. a) Go to Configuration-->Comms Settings Management-->Interfaces--> Select the shelf-->Select LAN in Interface Type tab-->Then select the alarmed ILAN port and compare configuration parameters. Open a session with the router and enter the following command in global configuration mode: mpls ldp router-id interface [ ]force. The "Create configuration setting" dialog displays. Service diversity and flexibility with the 6500-D7/S8 6500-D7 Optical Type 2 with AC power Cost-effective WDM configuration with ROADM 6500-S8 Packet-Optical with DC power Compact 600G Packet/OTN Switch This capability supports DCN Example 4 in the 6500 Packet-Optical Platform Data Communications Planning and User Guide, 323-1851-101. From 800G performance optics and 400G coherent pluggables to control plane automation, you can seamlessly maximize your investment into the future with. Resolution/Answer. Continually stay ahead of unpredictable customer demands with Ciena’s proven 6500 D/S-Series Packet Optical Platforms. All tasks in this section start on the Geolocation Setup/Configuration page. The physical infrastructure setup (LLDP) must be available. When i ssh to the open gear and try to get to the console for 6500, doesn't seem to work. I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Allow Admin—Select to have this interface act. 3 | P a g e 1 Introduction The Ciena 6500 S-Series and D-Series Packet Optical Platform, the Target of Evaluation (TOE), is a family of standalone hardware devices that run VxWorks and provide OSI Layer 0/1/2 network traffic management services. Installation. Once you are in Documentation you can scroll down for 6500 and click over it, You will find various. In the MCP UI, select System. A backup profile contains details of the backup process, backup transfer locations and number of backup files to be maintained for the NE. Number of Views 590.